Description
Supra LoRad 3 x 1.5 mmMkII
LoRad protects both from alternating fields radiating from the cable as well as from pick-up of surrounding airborne noise fields, e.g. wireless and mobile phones, wifi, radio and TV broadcasts, etc. LoRad MkII is a development of the LoRad concept, now withimproved shielding, flexibility, bend-/fatigue-resistance and strength.
In addition to the physical shield incorporated in the cable design, the leads are spun in a short pitch, counteracting the magnetic alternating field that according to the physical law of inductance always surrounds a lead that carries a current.
The benefits are less noise picked up by the cable, less noise caused by the cable inside and less noise that infect adjacent cables such as low level interconnects. You will notice cleaner sound, pronounced transients, richer fine detailsand an improved 3D soundstage. If your equipment is installed using Supra cables, is connected with the mains power in phase, the noise floor is normally suppressed by several dB, allowing more of the content to be revealed. Low radiating cables is also increasingly important from a health point of view. Science has proven that alternating magnetic fields affects cell growth.
LoRad MkII now incorporates Supra’s unique Carbon/Nylon shieldconcept. Semiconducting Carbon/Nylon shield displays improved properties, bending strength, environmental immunity, higher tensile strength and less microphonic effect. The Carbon/Nylon shieldis connected to a drain-wire along its total length, efficiently leading noise stuck in the shield to ground. We have tested and evaluated all known types of screens for making such a good cable as possible. Supra?s semi-conductive Carbon/Nylon shield was the only that passed the rigorous safety requirements and, moreover, its shielding properties was the best ever. LoRad MkII is tested and certified by Intertek Sweden, meeting the European safety regulation HD21.5 S3.The cable must be connected to a wall socket with a ground terminal for the full LoRad effect.
N.B.Every now and then we hear about creative alternative ways to arrange an earth connection if the wall socket does not provide one. There is especially onewe would like to highlight as particularly hazardous and we hope this statement does not serve as yet another creative way. Occasionally the water heat radiators have been connected to the hi-fi gear cabinets or to a mains distributionblock groundcontact plate. This works normally from the electrical point of view.Until the following happens; one of the devices become faulty and the cabinet becomes energized with wall socket mains voltage. The water radiator system maynot be properly grounded to earth potential. Now, this means that there might not be a large enough fault current through the water pipes to blow the fuse, thus disconnecting the fualty device. Further it means that most of the pipings and radiators are energized with wall socket mains voltage. If this is in an apartment house, every neighbour tenant has potentially lethal voltage in their radiators. It will not show. Until e.g.small children touches the radiator. Westrongly discouragesfrom the above or any other way to arrange a ground connection other than according to the local laws and regulations for electrical safety.
Mechanical data
Reviews
There are no reviews yet.