Sale!
In Stock

Supra Mains Cables Lorad 3×1.5 (Sold as per metre)(Made in Sweden)

$25.00

Features and benefits

  • LoRad stands for low radiation of electric and magnetic alternating fields, keeping you and your family free from harmful influence
  • The screen protects your equipment from radiated mains, RF pick-up and allows you to enjoy your hi-fi set or TV’s full potential
  • Short pitch twisting of the lead cores cancels the magnetic alternating fields and will not infect adjacent interconnects with noise feedback
  • LoRad will result in a cleaner sound, better picture and a more healthy home and working invironment with low levels of harmful fields.

78 in stock

SKU: AA000718 Category:

Description

Supra LoRad 3 x 1.5 mmMkII

LoRad protects both from alternating fields radiating from the cable as well as from pick-up of surrounding airborne noise fields, e.g. wireless and mobile phones, wifi, radio and TV broadcasts, etc. LoRad MkII is a development of the LoRad concept, now withimproved shielding, flexibility, bend-/fatigue-resistance and strength.

In addition to the physical shield incorporated in the cable design, the leads are spun in a short pitch, counteracting the magnetic alternating field that according to the physical law of inductance always surrounds a lead that carries a current.

The benefits are less noise picked up by the cable, less noise caused by the cable inside and less noise that infect adjacent cables such as low level interconnects. You will notice cleaner sound, pronounced transients, richer fine detailsand an improved 3D soundstage. If your equipment is installed using Supra cables, is connected with the mains power in phase, the noise floor is normally suppressed by several dB, allowing more of the content to be revealed. Low radiating cables is also increasingly important from a health point of view. Science has proven that alternating magnetic fields affects cell growth.

LoRad MkII now incorporates Supra’s unique Carbon/Nylon shieldconcept. Semiconducting Carbon/Nylon shield displays improved properties, bending strength, environmental immunity, higher tensile strength and less microphonic effect. The Carbon/Nylon shieldis connected to a drain-wire along its total length, efficiently leading noise stuck in the shield to ground. We have tested and evaluated all known types of screens for making such a good cable as possible. Supra?s semi-conductive Carbon/Nylon shield was the only that passed the rigorous safety requirements and, moreover, its shielding properties was the best ever. LoRad MkII is tested and certified by Intertek Sweden, meeting the European safety regulation HD21.5 S3.The cable must be connected to a wall socket with a ground terminal for the full LoRad effect.

N.B.Every now and then we hear about creative alternative ways to arrange an earth connection if the wall socket does not provide one. There is especially onewe would like to highlight as particularly hazardous and we hope this statement does not serve as yet another creative way. Occasionally the water heat radiators have been connected to the hi-fi gear cabinets or to a mains distributionblock groundcontact plate. This works normally from the electrical point of view.Until the following happens; one of the devices become faulty and the cabinet becomes energized with wall socket mains voltage. The water radiator system maynot be properly grounded to earth potential. Now, this means that there might not be a large enough fault current through the water pipes to blow the fuse, thus disconnecting the fualty device. Further it means that most of the pipings and radiators are energized with wall socket mains voltage. If this is in an apartment house, every neighbour tenant has potentially lethal voltage in their radiators. It will not show. Until e.g.small children touches the radiator. Westrongly discouragesfrom the above or any other way to arrange a ground connection other than according to the local laws and regulations for electrical safety.

Mechanical data

Standard Mains power flex with ground lead and high-end shield

Leads 3 x 1.5mm, tin plated 5N oxygen-free copper

Number of strands 204 pieces
Strand dimension ?0.10 mm
Di-electric (insulation) Dual layer PVC. Lead identification; green/yellow, blue & brown.

Number of fillers/armoring Yarn, 3 pieces
Shield interconnection to ground Drain wire, ultra flexible, tinplated, 66 strands x ? 0.07 mmOFC.

Armoring and insulation Woven polyester tape

Shield Woven semi-conductive Carbon/Nolyn tape

Jacket Age and heat resistant PVC

Outer dimension ? 9.2 mm
Resistance / conductor 10.8 Ohm / km
Nominal voltage 110 – 250 Volts
Maximal continuous current 10 Ampere